0.6/1 kV - armoured single core fire resistance cables

Applied standards: IEC 60502-1, IEC 60331

 

 

NOMINAL CROSS SECTION AREA

 

INSULATION THICKNESS

DIA. OF ARMOURED WIRES

SHEATH THICKNESS

APPROX. OVERALL DIAMETER

CONDUCTOR RESISTANCE AT 20°C

PACKING LENGTH

   

(mm2)

   

(mm)

(mm)

(mm)

(mm)

(Ω/km)

(m)

1x1.5

   

0.7

0.8

1.8

10.5

12.1

1000

1x1.25

   

0.7

0.8

1.8

11

7.41

1000

1x4

   

0.7

0.8

1.8

11.5

4.61

1000

1x6

   

0.7

0.8

1.8

12

3.08

1000

1x10

   

0.7

0.8

1.8

13

1.83

1000

1x16

   

0.7

0.8

1.8

14

1.15

1000

1x25

   

0.9

0.8

1.8

16

0.727

1000

1x35

   

0.9

1.25

1.8

18

0.524

1000

1x50

   

1.0

1.25

1.8

19

0.387

1000

1x70

   

1.1

1.25

1.8

21

0.268

1000

1x95

   

1.1

1.6

1.8

24

0.193

1000

1x120

   

1.2

1.6

1.8

26

0.153

1000

1x150

   

1.4

1.6

1.8

28

0.124

1000

1x185

   

1.6

1.6

1.8

30

0.0991

1000

1x240

   

1.7

1.6

1.9

33

0.0754

500

1x300

   

1.8

2.0

2.0

36

0.0601

500

1x400

   

2.0

2.0

2.2

41

0.0470

500

1x500

   

2.2

2.0

2.23

45

0.03666

500